Logs: agents, syslog and SNMP traps
Questi contenuti non sono ancora disponibili nella tua lingua.
DumbMonit can keep the log lines of your machines and equipment next to their metrics, search them, and alert on patterns. Everything lands in the embedded VictoriaLogs and is searched on the admin-only Logs page with LogsQL.
What can feed it
Section titled “What can feed it”| Source | Stream (service) | How |
|---|---|---|
| DumbMonit itself | dumbmonit | Always, once the store is on. |
| Agents | agent | Per machine, from its device page. |
| Syslog | syslog | The built-in server (UDP and TCP). |
| SNMP traps | trap | The built-in receiver (v1, v2c). |
Every line has level (error, warn, info, debug), host, origin
(journald unit, file, event log channel or sender address) and, when the
sender is one of your devices, target (its id) and target_name.
Agent log collection
Section titled “Agent log collection”Open an agent device and use Log collection. It is off until you switch it on; the agent applies the setting at its next report, with no restart.
- systemd journal (Linux): new entries from now on, filtered by priority.
- Followed files: absolute paths with
*and?in each component, for example/var/log/nginx/*.log. Rotation and truncation are followed; lines already in a file when collection starts are not replayed. Levels are guessed from the wordserror,warn,debug. - Windows event log channels:
System,Application… read through PowerShell every 15 seconds. - Minimum level: lines below it are never sent.
Lines travel over the agent’s usual channel (same server, same port, same
token or certificate) in batches. If the server cannot be reached the agent
keeps up to 8 MiB on disk (next to its binding secret) and sends them when it
comes back; beyond that, the oldest are dropped. Set DUMBMONIT_AGENT_LOGS=off
in the agent’s environment to forbid collection on a machine whatever the
server asks.
Syslog server
Section titled “Syslog server”Off by default. Set DUMBMONIT_SYSLOG_ENABLED=true, publish the port in your
Compose file (5514/udp and 5514/tcp, unprivileged because the container
does not run as root), and point your equipment at it. RFC 3164 and RFC 5424
are understood, with newline-delimited or octet-counted TCP framing. The
sender is attached to the device whose address is the source IP (or, failing
that, whose name is the hostname in the message). Port 514 can be redirected to
5514 on the host or the router. Variables: see
Configuration.
SNMP traps
Section titled “SNMP traps”Off by default (DUMBMONIT_TRAPS_ENABLED=true, port 1162/udp). SNMP v1 and
v2c traps and v2c informs (acknowledged) are received; v3 is not supported
and such messages are counted as refused. Set DUMBMONIT_TRAPS_COMMUNITIES to
accept only your communities. Each trap becomes a line named after the trap
(linkDown, coldStart…, or the OID) followed by its variable bindings, which
are named after the built-in SNMP profiles when they know the OID.
Searching
Section titled “Searching”The Logs page adds a Source (server, agents, syslog, SNMP traps, all) and a Device filter to the period, minimum level and LogsQL query. A device page has a Logs button that opens the page already filtered. The Receivers block shows what listens and what arrived.
Alerting on a pattern
Section titled “Alerting on a pattern”Open Alert on this search below the search form: it creates a log pattern
rule from the current source, level and query. The rule counts matching lines
over a sliding window (1 minute to 24 hours) and fires when the count reaches
your threshold, per device (one alert per target) or overall. It is a
normal alert rule: severity, hold time, channels, silences, dependency
suppression, history and backups all apply, and it can be edited on the
Alerts page.
Examples (the query part):
service:=syslog "Failed password"— failed logins reported through syslog;service:=trap level:in("error", "warn")— link-down and authentication traps, which is how you turn a trap into an alert;service:=agent origin:"file:/var/log/nginx/error.log"— nginx errors.
Rules only accept filters (no | pipes). A rule watching a log source that
stays silent never fires: a count of zero is “no problem”, so use >= with a
threshold of at least 1.